Heavy Duty Rubber, Enhanced Version 4G16

H07RN-F, ENHANCED VERSION, Heavy duty rubber cable, halogen-free, water submersible, HAR approved 4G16 (3 + E)

Free shipping on Web orders over $100

$64.00
(Per/m excl GST)
In Stock
Quantity Breaks
1+
10+
50+
$64.00
$64.00
$64.00
SKU: LAPP-4533073 Manufacturer part number: 4533073

Benefits

  • Arrangements made of single-core, rubber-sheathed cables H07RN-F can be used for short circuit-proof and short-to-ground-proof installations in accordance with IEC 60364-5-52/ HD 60364-5-52/ VDE 0100 Part 520
  • More water-resistant than H07RN-F and H07RN8-F
  • Conductor temperature range more suitable for outdoor installation and wider than H07RN-F, H07ZZ-F, H07BN4-F und NSSHÖU

Application range

  • Medium, mechanical stress and industrial and agricultural use as well as for handheld and power supply devices (H07RN-F according to EN 50565-2)
  • Drip loop torsion between the nacelle and the tower of wind turbine generators/ windmills
  • Outdoors acc. EN 50565-2
  • For buildings or industrial plants with a high density of people or valuable assets

Product features

  • Oil resistant according to EN 60811-404; Good resistance to abrasion, atmospheric agents, grease and mineral oils
  • UV-, Ozone- (acc. EN 60811), Cold- (-40 °C flexible at the conductor) and Heat-resistant (+90 °C at the conductor)
  • Drip loop torsion resistant (wind turbine) ==>TW-0, TW-1 and TW-2: -40 °C to +90 °C/ 2,000 cycles (5,000 cycles from +5 °C)/ torsion angle of +/-150 ° per metre at one revolution per minute
  • Long-time water submersion (AD8) down to 100 m without interruption (no drinking water, minimum water temperature of +5 °C, standing water only, no areas with boat/ ship/ submarine traffic)
  • Halogen-free according to EN 60754 (sub-parts -1 and -2), 
    flame-retardant according to IEC 60332-1-2 and low smoke density (LS) according to EN 61034-2

Norm references / Approvals

  • <HAR> H07RN-F cable type approval according to EN 50525-2-21

Product Make-up

  • Conductor made of bare copper wires
  • Core insulation: special rubber
  • Outer sheath: special rubber compound
 
SKU
LAPP-4533073
We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
Products specifications
Attribute name Attribute value
Locally Stocked in Australia Only Show Stocked Items
Number of Conductors 4
Conductor Size 16mm
Colour Black
*
*
*
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Benefits

  • Arrangements made of single-core, rubber-sheathed cables H07RN-F can be used for short circuit-proof and short-to-ground-proof installations in accordance with IEC 60364-5-52/ HD 60364-5-52/ VDE 0100 Part 520
  • More water-resistant than H07RN-F and H07RN8-F
  • Conductor temperature range more suitable for outdoor installation and wider than H07RN-F, H07ZZ-F, H07BN4-F und NSSHÖU

Application range

  • Medium, mechanical stress and industrial and agricultural use as well as for handheld and power supply devices (H07RN-F according to EN 50565-2)
  • Drip loop torsion between the nacelle and the tower of wind turbine generators/ windmills
  • Outdoors acc. EN 50565-2
  • For buildings or industrial plants with a high density of people or valuable assets

Product features

  • Oil resistant according to EN 60811-404; Good resistance to abrasion, atmospheric agents, grease and mineral oils
  • UV-, Ozone- (acc. EN 60811), Cold- (-40 °C flexible at the conductor) and Heat-resistant (+90 °C at the conductor)
  • Drip loop torsion resistant (wind turbine) ==>TW-0, TW-1 and TW-2: -40 °C to +90 °C/ 2,000 cycles (5,000 cycles from +5 °C)/ torsion angle of +/-150 ° per metre at one revolution per minute
  • Long-time water submersion (AD8) down to 100 m without interruption (no drinking water, minimum water temperature of +5 °C, standing water only, no areas with boat/ ship/ submarine traffic)
  • Halogen-free according to EN 60754 (sub-parts -1 and -2), 
    flame-retardant according to IEC 60332-1-2 and low smoke density (LS) according to EN 61034-2

Norm references / Approvals

  • <HAR> H07RN-F cable type approval according to EN 50525-2-21

Product Make-up

  • Conductor made of bare copper wires
  • Core insulation: special rubber
  • Outer sheath: special rubber compound
 
SKU
LAPP-4533073
Products specifications
Attribute name Attribute value
Locally Stocked in Australia Only Show Stocked Items
Number of Conductors 4
Conductor Size 16mm
Colour Black

Customers who bought this item also bought

ÖLFLEX® CLASSIC 110, PVC sheath, numbered cores, VDE-registered 4X1 (No Earth) LAPP-1119854
$3.46
(Per/m excl GST)
In Stock
INSTRUM RE-Y(ST)Y PiMF Individual & Overall Screened, 4X2X0.5 BK LAPP-1271052
$8.34
(Per/m excl GST)
In Stock
PCE CEE-connector 63A 4p 6h IP67 POWER TWIST PCE-234-6
$188.00
(Each excl GST)
In Stock
EPIC® H-A 4 Ss 4p+E Male Insert, Screw Termination LAPP-10431000
$7.73
(Each excl GST)
In Stock
EPIC® H-A 4 Bs 4p+E Female Insert, Screw Termination LAPP-10432000
$7.42
(Each excl GST)
In Stock