You have no items in your shopping cart.

Multi-Standard UL/CSA 25XAWG22

UNITRONICĀ® 300, UL/CSA rated unscreened, 25XAWG22 (0.34mm2) GY 300V

Free shipping on Web orders over $100

$56.00 (Per/m excl GST)
Global Stock
Quantity Breaks
1+
10+
50+
$56.00
$56.00
$56.00
SKU: LAPP-302225 Manufacturer part number: 302225

Benefits

  • Wide application range due to multiple certifications
  • Cost-saving, easy installation due to omission of closed raceways (suitable for open wiring)

Application range

  • Control and signal cables for internal and external wiring
  • For the North American market
  • On the basis of CMG, PLTC or ITC direct laying on cable tray in the USA, in conjunction with -ER (Exposed Run) for unprotected transition sections with a length of not more than 6 ft. each
  • Thanks to the DIRECT BURIAL approval, direct burial of versions with the nominal conductor cross sections 18 AWG and 16 AWG is normatively permitted in the USA
  • Torsion resistant up to ±150 °/m for the drip loop of wind turbine generators

Product features

  • Oil-resistant according to UL OIL RES I
  • Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)

Norm references / Approvals

  • USA: (UL) CMG [E130334], (UL) PLTC-ER (18 AWG + 16 AWG) [E216027], (UL) PLTC (>24 AWG) [E216027], (UL) ITC-ER (18 AWG + 16 AWG) [E196134], UL AWM Style 2464 [E100338], DIR BUR (18 AWG + 16 AWG)
  • CAN: c(UL) CMG FT4 [E130334], CSA AWM I/II A/B FT1

Product Make-up

  • Fine-wire strand made of tinned-copper wires
  • Core insulation made of PVC compound
  • UNITRONIC® 300 S: with overall foil tape wrapping, drain wire,
    tin-plated copper braiding (75 % coverage)
  • Outer jacket: Specially Formulated PVC
  • Color of the outer jacket: Dark gray (similar to RAL 7005)

Temperature range

  • Occasional flexing/ North America: -25°C to +105°C (AWM for USA: +80°C)
  • Fixed installation/ North America: -40°C to +105°C (AWM for USA: +80°C)

Nominal voltage

  • according to UL: 300 V
    IEC: not for power transmission
 
SKU
LAPP-302225
We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
Products specifications
Attribute name Attribute value
Locally Stocked in NZ Only Show Stocked Items
*
*
*
Product Files
Type Name File Name / Description

Benefits

  • Wide application range due to multiple certifications
  • Cost-saving, easy installation due to omission of closed raceways (suitable for open wiring)

Application range

  • Control and signal cables for internal and external wiring
  • For the North American market
  • On the basis of CMG, PLTC or ITC direct laying on cable tray in the USA, in conjunction with -ER (Exposed Run) for unprotected transition sections with a length of not more than 6 ft. each
  • Thanks to the DIRECT BURIAL approval, direct burial of versions with the nominal conductor cross sections 18 AWG and 16 AWG is normatively permitted in the USA
  • Torsion resistant up to ±150 °/m for the drip loop of wind turbine generators

Product features

  • Oil-resistant according to UL OIL RES I
  • Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)

Norm references / Approvals

  • USA: (UL) CMG [E130334], (UL) PLTC-ER (18 AWG + 16 AWG) [E216027], (UL) PLTC (>24 AWG) [E216027], (UL) ITC-ER (18 AWG + 16 AWG) [E196134], UL AWM Style 2464 [E100338], DIR BUR (18 AWG + 16 AWG)
  • CAN: c(UL) CMG FT4 [E130334], CSA AWM I/II A/B FT1

Product Make-up

  • Fine-wire strand made of tinned-copper wires
  • Core insulation made of PVC compound
  • UNITRONIC® 300 S: with overall foil tape wrapping, drain wire,
    tin-plated copper braiding (75 % coverage)
  • Outer jacket: Specially Formulated PVC
  • Color of the outer jacket: Dark gray (similar to RAL 7005)

Temperature range

  • Occasional flexing/ North America: -25°C to +105°C (AWM for USA: +80°C)
  • Fixed installation/ North America: -40°C to +105°C (AWM for USA: +80°C)

Nominal voltage

  • according to UL: 300 V
    IEC: not for power transmission
 
SKU
LAPP-302225
Products specifications
Attribute name Attribute value
Locally Stocked in NZ Only Show Stocked Items