PROFINET Coupler PN / EtherNetIP

 

With the PN/EtherNetIP Coupler, a simple and uncomplicated connection of a PROFINET machine to an EtherNet/IP machine is possible. The PN/EtherNetIP Coupler allows data transmission between a PROFINET controller and an EtherNet/IP PLC.

Received input data on one side of the network are made available as output data on the other side of the network to the PLC. The I/O data exchange takes place live and as fast as possible without further handling blocks.

The maximum size of the transferable I/O data is 1024 bytes. Up to 3 input and 3 output assemblies can be configured on the EtherNet/IP network side. Up to 300 slots are available for I/O modules.

The integration into the PLC engineering tool is made possible by a GSDML file, an extra configuration software is not necessary. The configuration of the I/O data to be exchanged is performed in the Siemens engineering tool. An EDS file matching the configuration can then be downloaded from the website by the PN/EtherNetIP Coupler and used to configure the EtherNet/IP PLC.

General information

  • Dimensions (DxWxH)32.5 x 58.5 x 76 mm mm
  • WeightApprox. 135 g

PROFINET interface (X1)

  • Number 1
  • Connection 2 x RJ45, integrated switch
  • Protocol PROFINET IO Device as defined in IEC 61158-6-10
  • Transmission rate 100 Mbps full duplex
  • I/O image size max. 1024 bytes of input and output data
  • Features
    • media redundancy(MRP-Client),
    • automatic addressing,
    • Topologieerkennung (LLDP, DCP),
    • diagnosis alarms
    • PROFINET conformance class B

EtherNet/IP interface (X2)

  • Number 1
  • Connection 2x RJ45, integrated switch
  • Protocol EtherNet/IP
    • implicit messaging (Transport Class 1)
    • explicit messaging (Transport Class 3)
  • Transmission rate 10/100 Mbit/s, full-/half duplex
  • I/O image size
    • 3x input assemblies + 3x output assemblies
    • together maximum 1024 bytes data
    • Number of the assemblies adjustable

Status indicator

  • Function indicator 9 LEDs
  • Ethernet status 8 LEDs

Power supply

  • Operating voltage 24 V DC (18 - 28 V DC)
  • Current draw max. 140 mA
  • Power dissipation max. 3.4 W

Ambient conditions

  • Ambient temperature 0 °C to 60 °C
  • Transport and storage temperature -20 °C to 80 °C
  • Relative air humidity 95% non-condensing
  • Protection rating IP 20
  • Certifications CE, UL

CE

  • RoHS Yes
  • REACH Yes

UL

  • UL UL 61010-1 / UL 61010-2-201
  • Surrounding Air Temperature DC 24 V (18 ... 28 VDC, SELV and limited energy circuit)
  • Pollution degree 2
  • Altitude Up to 2000m
  • Temperature cable rating 87 °C

 

SKU: HELMZ-700-160-3EN02

MPN: 700-160-3EN02

We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
*
*
*
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

PROFINET Coupler PN / EtherNetIP

 

With the PN/EtherNetIP Coupler, a simple and uncomplicated connection of a PROFINET machine to an EtherNet/IP machine is possible. The PN/EtherNetIP Coupler allows data transmission between a PROFINET controller and an EtherNet/IP PLC.

Received input data on one side of the network are made available as output data on the other side of the network to the PLC. The I/O data exchange takes place live and as fast as possible without further handling blocks.

The maximum size of the transferable I/O data is 1024 bytes. Up to 3 input and 3 output assemblies can be configured on the EtherNet/IP network side. Up to 300 slots are available for I/O modules.

The integration into the PLC engineering tool is made possible by a GSDML file, an extra configuration software is not necessary. The configuration of the I/O data to be exchanged is performed in the Siemens engineering tool. An EDS file matching the configuration can then be downloaded from the website by the PN/EtherNetIP Coupler and used to configure the EtherNet/IP PLC.

General information

  • Dimensions (DxWxH)32.5 x 58.5 x 76 mm mm
  • WeightApprox. 135 g

PROFINET interface (X1)

  • Number 1
  • Connection 2 x RJ45, integrated switch
  • Protocol PROFINET IO Device as defined in IEC 61158-6-10
  • Transmission rate 100 Mbps full duplex
  • I/O image size max. 1024 bytes of input and output data
  • Features
    • media redundancy(MRP-Client),
    • automatic addressing,
    • Topologieerkennung (LLDP, DCP),
    • diagnosis alarms
    • PROFINET conformance class B

EtherNet/IP interface (X2)

  • Number 1
  • Connection 2x RJ45, integrated switch
  • Protocol EtherNet/IP
    • implicit messaging (Transport Class 1)
    • explicit messaging (Transport Class 3)
  • Transmission rate 10/100 Mbit/s, full-/half duplex
  • I/O image size
    • 3x input assemblies + 3x output assemblies
    • together maximum 1024 bytes data
    • Number of the assemblies adjustable

Status indicator

  • Function indicator 9 LEDs
  • Ethernet status 8 LEDs

Power supply

  • Operating voltage 24 V DC (18 - 28 V DC)
  • Current draw max. 140 mA
  • Power dissipation max. 3.4 W

Ambient conditions

  • Ambient temperature 0 °C to 60 °C
  • Transport and storage temperature -20 °C to 80 °C
  • Relative air humidity 95% non-condensing
  • Protection rating IP 20
  • Certifications CE, UL

CE

  • RoHS Yes
  • REACH Yes

UL

  • UL UL 61010-1 / UL 61010-2-201
  • Surrounding Air Temperature DC 24 V (18 ... 28 VDC, SELV and limited energy circuit)
  • Pollution degree 2
  • Altitude Up to 2000m
  • Temperature cable rating 87 °C

 