Power Measurement 3-Phase 690 VAC

The voltage is measured via network connection to L1, L2, L3 and N

Free shipping on Web orders over $100

$1131.00
(Each excl GST)
In Stock
Quantity Breaks
1+
5+
25+
$1,131.00
$1,131.00
$1,131.00
SKU: WAGO-750-495/000-002 Manufacturer part number: 750-495/000-002 Manufacturer: WAGO

Technical data

Number of measurement inputs 7 (3 Spannungsmesseingänge, 4 differentielle Strommesseingänge)
Signal type Power measurement
Signal form Any periodic signals (considering the threshold frequencies)
Resolution [bit] 24bits
Data width 2 x 128-bit data; 2 x 64-bit control/status
Voltage path input resistance (typ.) 1429kΩ
Current path input resistance (typ.) 44 kΩ
Reference for measurement error AC current/voltage
Measurement error (reference temperature) 25°C
Measurement error, deviation (max.) from the upper-range value 0.5%
Measurement current (max.) Rogowski Coils RT500/RT2000
Measurement cycle time Adjustable for arithmetic mean value, Min_Max_Values
Frequency range (mains frequency) 45 … 65 Hz
Frequency range (harmonics analysis) 0 … 3300 Hz
Limit frequency 15.9kHz
Rated voltage VLN = 400 VAC; VLL = 690 VAC
Calculated values Line-to-line voltage, power output, energy, power factors, mains frequency, harmonic analysis (up to the 41st harmonic), THD
Measurement components Evaluating
Measurement method True RMS measurement
Configuration options WAGO-I/O-CHECK; CODESYS Library; e!COCKPIT
Supply voltage (system) 5 VDC; via data contacts
Current consumption (5 V system supply) 100mA
Isolation 6 kV system/field
Rated surge voltage 6 kV
 
SKU WAGO-750-495/000-002
We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
Products specifications
Attribute name Attribute value
Locally Stocked in Australia Only Show Stocked Items
*
*
*
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Technical data

Number of measurement inputs 7 (3 Spannungsmesseingänge, 4 differentielle Strommesseingänge)
Signal type Power measurement
Signal form Any periodic signals (considering the threshold frequencies)
Resolution [bit] 24bits
Data width 2 x 128-bit data; 2 x 64-bit control/status
Voltage path input resistance (typ.) 1429kΩ
Current path input resistance (typ.) 44 kΩ
Reference for measurement error AC current/voltage
Measurement error (reference temperature) 25°C
Measurement error, deviation (max.) from the upper-range value 0.5%
Measurement current (max.) Rogowski Coils RT500/RT2000
Measurement cycle time Adjustable for arithmetic mean value, Min_Max_Values
Frequency range (mains frequency) 45 … 65 Hz
Frequency range (harmonics analysis) 0 … 3300 Hz
Limit frequency 15.9kHz
Rated voltage VLN = 400 VAC; VLL = 690 VAC
Calculated values Line-to-line voltage, power output, energy, power factors, mains frequency, harmonic analysis (up to the 41st harmonic), THD
Measurement components Evaluating
Measurement method True RMS measurement
Configuration options WAGO-I/O-CHECK; CODESYS Library; e!COCKPIT
Supply voltage (system) 5 VDC; via data contacts
Current consumption (5 V system supply) 100mA
Isolation 6 kV system/field
Rated surge voltage 6 kV
 
SKU WAGO-750-495/000-002