Communication |
Modbus (TCP, UDP) ETHERNET Modbus® RTU RS-232 serial interface RS-485 interface EtherNet/IPTM Adapter (slave), library for e!RUNTIME MQTT |
ETHERNET protocols |
DHCP DNS NTP FTP FTPS SNMP HTTP HTTPS SSH |
Visualization |
Web-Visu Web Visu |
Operating system |
Real-time Linux (with RT-Preempt patch) |
CPU |
Cortex A8; 600 MHz |
Programming languages per IEC 61131-3 |
Instruction List (IL) Ladder Diagram (LD) Function Block Diagram (FBD), Continuous Function Chart (CFC) Structured Text (ST) Sequential Function Chart (SFC) |
Programming environment |
e!COCKPIT (based on CODESYS V3) WAGO-I/O-PRO V2.3 (based on CODESYS V2.3) |
Configuration options |
e!COCKPIT WAGO-I/O-CHECK Web-Based Management |
Security encryption |
OpenVPN, IPsec, firewall |
Services |
SMS (bidirectional) GPRS connection to Internet |
Radio technology |
GSM/Edge/UMTS/HSPA+ |
Frequency band |
GSM quad-band |
Baud rate (communication/fieldbus 1) |
10/100 Mbit/s |
Baud rate |
ETHERNET: 10/100 Mbit/s |
Transmission medium (communication/fieldbus) |
ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length |
Main memory (RAM) |
256MB |
Internal memory (flash) |
256MB |
Non-volatile hardware memory |
128 |
Program memory |
CODESYS V2: 16 MB; e!RUNTIME: 60 MB (Program and data memory (dynamically distributed)) |
Data memory |
CODESYS V2: 64 MB; e!RUNTIME: 60 MB Program and data memory (dynamically distributed) |
Non-volatile software memory |
128 |
Non-volatile software memory |
128. |
Type of memory card |
SD and SDHC up to 32 GB (all guaranteed properties only valid with WAGO 758-879/000-001 Memory Card) |
Memory card slot |
Push-push mechanism; Cover lid (sealable) |
SIM card type |
Mini-SIM |
SIM card slot |
Push-push mechanism |
Number of modules per node (max.) |
250 |
Number of modules without a bus extension (max.) |
64 |
Input and output process image (internal) max. |
1000 words/1000 words |
Input and output process image (Modbus®) max. |
CODESYS V2: 1000 words/1000 words |
Indicators |
LED (SYS, RUN, I/O, USR, S1–S5, NET) red/green/orange: System status, program, local data bus, status programmable by user (can be used via CODESYS library); signal strength S1–S5, network status; LED (CON, A, B) green: Mobile network status, system power supply status, field supply status |
Supply voltage (system) |
24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection) |
Input current (typ.) at nominal load (24 V) |
550mA |
Total current (system supply) |
700mA |
Supply voltage (field) |
24 VDC (-25 … +30 %); via power jumper contacts |
Current carrying capacity (power jumper contacts) |
10A |
Number of outgoing power jumper contacts |
3 |
Isolation |
500 V system/field |