Power Supply Eco 1-phase 24VDC 2.5A

Power supply; Eco; 1-phase; 24 VDC output voltage; 2.5 A output current; DC-OK LED; 4,00 mm²

Free shipping on Web orders over $100

$225.00
(Each excl GST)
On Request
Quantity Breaks
1+
5+
25+
$225.00
$225.00
$225.00
SKU: WAGO-787-712 Manufacturer part number: 787-712 Manufacturer: WAGO

Technical data

Input

Phases 1
Nominal input voltage Ui nom 1 x AC 110 … 240 V
Input voltage range 1 x AC 85 … 264 V; DC 90 … 373 V
Nominal mains frequency range 47 … 63 Hz; 0 Hz
Input current Ii ≤ 0.7 A (230 VAC); ≤ 1.2 A (115 VAC)
Discharge current ≤ 1 mA
Inrush current ≤ 30 A
Power factor ≥ 0.5  (230 VAC)
Power factor correction (PFC) Passive
Mains failure hold-up time ≥ 20 ms (230 VAC)

Output

Nominal output voltage Uo nom DC 24 V (SELV)
Output voltage range DC 22 … 28 V (adjustable)
Default setting DC 24 V
Nominal output current Io nom 2.5 A (24 VDC)
Nominal output power 60W
Deviation ≤ 1 %
Residual ripple ≤ 100 mV (peak-to-peak)
Overload behavior Constant power (in overload range: 1.15 … 1.4 x Io nom); Shutdown and automatic restart in the event of a short circuit

Signaling and communication

Signaling 1 x LED DC OK (green)
1 x Overload LED (red)
Operation status indicator Green LED (24 VDC OK)
Red LED (overload)

Efficiency/power losses

Power loss Pl ≤ 8.3 W (230 VAC; Nominal load)
Power loss (max.) Pl (max.) 11.5 W (110 VAC / 24 VDC; 2.75 A)
Efficiency (typ.) 86 % (230 VAC)

Circuit protection

Internal fuse F 2.5 A / 250 VAC
Required backup fusing An external DC fuse is required for the DC input voltage.
Recommended backup fusing Circuit breaker: 10 A, 16 A; Tripping characteristic: B or C

Safety and protection

Isolation voltage (pri.-sec.) DC 4.242 kV
Isolation voltage (pri.-PE) DC 2.2 kV
Isolation voltage (sec.-PE) DC 0.7 kV
Protection class I
Protection type IP20
Note on protection type Per EN 60529
Resistance to reverse feed ≤ DC 28 V
Overvoltage category II
Pollution degree 2
Transient suppression (primary) Varistor
Short-circuit-protected Yes
Open-circuit-proof Yes
Parallel operation Yes
Series operation Yes
MTBF 480,000 h (per IEC 61709)

 

SKU WAGO-787-712

GTIN 4045454908195

We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
*
*
*
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Product Files

Technical data

Input

Phases 1
Nominal input voltage Ui nom 1 x AC 110 … 240 V
Input voltage range 1 x AC 85 … 264 V; DC 90 … 373 V
Nominal mains frequency range 47 … 63 Hz; 0 Hz
Input current Ii ≤ 0.7 A (230 VAC); ≤ 1.2 A (115 VAC)
Discharge current ≤ 1 mA
Inrush current ≤ 30 A
Power factor ≥ 0.5  (230 VAC)
Power factor correction (PFC) Passive
Mains failure hold-up time ≥ 20 ms (230 VAC)

Output

Nominal output voltage Uo nom DC 24 V (SELV)
Output voltage range DC 22 … 28 V (adjustable)
Default setting DC 24 V
Nominal output current Io nom 2.5 A (24 VDC)
Nominal output power 60W
Deviation ≤ 1 %
Residual ripple ≤ 100 mV (peak-to-peak)
Overload behavior Constant power (in overload range: 1.15 … 1.4 x Io nom); Shutdown and automatic restart in the event of a short circuit

Signaling and communication

Signaling 1 x LED DC OK (green)
1 x Overload LED (red)
Operation status indicator Green LED (24 VDC OK)
Red LED (overload)

Efficiency/power losses

Power loss Pl ≤ 8.3 W (230 VAC; Nominal load)
Power loss (max.) Pl (max.) 11.5 W (110 VAC / 24 VDC; 2.75 A)
Efficiency (typ.) 86 % (230 VAC)

Circuit protection

Internal fuse F 2.5 A / 250 VAC
Required backup fusing An external DC fuse is required for the DC input voltage.
Recommended backup fusing Circuit breaker: 10 A, 16 A; Tripping characteristic: B or C

Safety and protection

Isolation voltage (pri.-sec.) DC 4.242 kV
Isolation voltage (pri.-PE) DC 2.2 kV
Isolation voltage (sec.-PE) DC 0.7 kV
Protection class I
Protection type IP20
Note on protection type Per EN 60529
Resistance to reverse feed ≤ DC 28 V
Overvoltage category II
Pollution degree 2
Transient suppression (primary) Varistor
Short-circuit-protected Yes
Open-circuit-proof Yes
Parallel operation Yes
Series operation Yes
MTBF 480,000 h (per IEC 61709)

 

SKU WAGO-787-712

GTIN 4045454908195