Analog I/P 4x I, 0/4...20mA, +-20 mA, 12 Bit

TB20, Analog input module - AI 4x I, 0/4...20mA, +-20 mA, 12 Bit

Free shipping on Web orders over $100

$437.00
(Each excl GST)
On Request
SKU: HELMZ-600-250-4AD01 Manufacturer part number: 600-250-4AD01 Manufacturer: HELMHOLZ

Analog-input-module, I, 12 Bit 4x

 

The scope of delivery already includes the appropriate front connector for the cabling and a base module. The module has 4 analog inputs.

 

General information

  • Dimensions (DxWxH) 110 x 14 x 73 mm
  • Weight Approx. 70 g
  • Number of inputs 4
  • Power dissipation Max. 0.7 W
  • Hot-swap capable Yes

Electrical isolation

  • from the backplane bus Yes
  • Between the channels No

Current draw

  • External Not needed
  • Internal Max. 95 mA

Measuring

  • Measuring ranges / load resistance
    • 0 ... 20 mA / 50 ohms,
    • 4 ... 20 mA / 50 ohms,
    • ±20 mA / 50 ohms
  • Measuring method Integration
  • Measurement resolution 11 bit + sign
  • Interference frequency suppression None | 10 Hz | 50 Hz | 60 Hz | 400 Hz
  • Refresh rate / conversion rate Number of active channels x conversion time + 16 ms for wire break detection when activated. The conversion time will depend on the interference frequency suppression:
    • None: 8 ms
    • 400 Hz: 45 ms
    • 60 Hz: 109 ms
    • 50 Hz: 128 ms
    • 10 Hz: 342 ms
  • Diagnoses Upper measuring range limit exceeded (overflow), lower measuring range limit fallen below (underflow), wire break (for 4 ... 20 mA only), parameter assignment error
  • Process alarms Upper and lower limit per channel

Error limits

  • Operational error limit in the entire temperature range ±0.5 % relative to the nominal range
  • Basic error limit at 25 °C ±0.3 % relative to the nominal range
  • Temperature error± 0.005 %/K relative to the nominal range
  • Linearity error± 0.05 %/K relative to the nominal range
  • Repeating accuracy in steady state at 25 °C ±0.05 %/K relative to the nominal range
  • Parameter configuration length 22 bytes
  • General error indicator Red LED
  • General error indicator Red LED

Ambient conditions

  • Ambient temperature 0 °C … +60 °C
  • Transport and storage temperature -20 °C … +80 °C
  • Relative air humidity 95 % r H without condensation
  • Protection rating IP 20
  • Certifications CE, UL

UL

  • Surrounding Air Temperature 0 °C … +60°C
  • Pollution degree 2

CE

  • Noise immunity DIN EN 61000-6-2 “EMC Immunity”
  • Interference emission DIN EN 61000-6-4 “EMC Emission”
  • Vibration and shock resistance DIN EN 60068-2-6:2008 „Vibration“, DIN EN 60068-2-27:2010 „Shock"
  • RoHS Yes
  • REACH Yes

 

SKU: HELMZ-600-250-4AD01

MPN: 600-250-4AD01

We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
*
*
*
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Product Files

Analog-input-module, I, 12 Bit 4x

 

The scope of delivery already includes the appropriate front connector for the cabling and a base module. The module has 4 analog inputs.

 

General information

  • Dimensions (DxWxH) 110 x 14 x 73 mm
  • Weight Approx. 70 g
  • Number of inputs 4
  • Power dissipation Max. 0.7 W
  • Hot-swap capable Yes

Electrical isolation

  • from the backplane bus Yes
  • Between the channels No

Current draw

  • External Not needed
  • Internal Max. 95 mA

Measuring

  • Measuring ranges / load resistance
    • 0 ... 20 mA / 50 ohms,
    • 4 ... 20 mA / 50 ohms,
    • ±20 mA / 50 ohms
  • Measuring method Integration
  • Measurement resolution 11 bit + sign
  • Interference frequency suppression None | 10 Hz | 50 Hz | 60 Hz | 400 Hz
  • Refresh rate / conversion rate Number of active channels x conversion time + 16 ms for wire break detection when activated. The conversion time will depend on the interference frequency suppression:
    • None: 8 ms
    • 400 Hz: 45 ms
    • 60 Hz: 109 ms
    • 50 Hz: 128 ms
    • 10 Hz: 342 ms
  • Diagnoses Upper measuring range limit exceeded (overflow), lower measuring range limit fallen below (underflow), wire break (for 4 ... 20 mA only), parameter assignment error
  • Process alarms Upper and lower limit per channel

Error limits

  • Operational error limit in the entire temperature range ±0.5 % relative to the nominal range
  • Basic error limit at 25 °C ±0.3 % relative to the nominal range
  • Temperature error± 0.005 %/K relative to the nominal range
  • Linearity error± 0.05 %/K relative to the nominal range
  • Repeating accuracy in steady state at 25 °C ±0.05 %/K relative to the nominal range
  • Parameter configuration length 22 bytes
  • General error indicator Red LED
  • General error indicator Red LED

Ambient conditions

  • Ambient temperature 0 °C … +60 °C
  • Transport and storage temperature -20 °C … +80 °C
  • Relative air humidity 95 % r H without condensation
  • Protection rating IP 20
  • Certifications CE, UL

UL

  • Surrounding Air Temperature 0 °C … +60°C
  • Pollution degree 2

CE

  • Noise immunity DIN EN 61000-6-2 “EMC Immunity”
  • Interference emission DIN EN 61000-6-4 “EMC Emission”
  • Vibration and shock resistance DIN EN 60068-2-6:2008 „Vibration“, DIN EN 60068-2-27:2010 „Shock"
  • RoHS Yes
  • REACH Yes

 

SKU: HELMZ-600-250-4AD01

MPN: 600-250-4AD01