You have no items in your shopping cart.

Buscoupler EtherCAT

TB20-C, Buscoupler EtherCAT

Free shipping on Web orders over $100

$468.00
(Each excl GST)
On Request
SKU: HELMZ-600-185-1AA11 Manufacturer part number: 600-185-1AA11 Manufacturer: HELMHOLZ

TB20 bus coupler EtherCAT

 

The EtherCAT bus coupler makes it possible to access data from peripheral modules using the EtherCAT protocol.
It can accommodate up to 64 modules of any kind connected in series with the bus coupler.
It detects peripheral modules that are plugged in and can assign the corresponding I/O data to an EtherCAT mapping automatically.
The EtherCAT bus coupler supports the Modular Device Profile.
A large I/O image table size of 1,024 bytes makes it possible toimplement comprehensive and complex systems.
TB20 ToolBox can be used to easily configure the system and the various module parameters and transfer the corresponding settings to the coupler.
Alternatively, the configuration can also be edited using the CoE object dictionary.
Finally, running TB20 systems can be diagnosed in real-time and set up for testing purposes if an EtherCAT master is not yet connected (simulation / I/O check).
A functioning TB20 configuration will always require a bus coupler and at least one peripheral module.

Note: Individual modules cannot be combined with the IO systems of other manufacturers.

General information

  • Dimensions (DxWxH) 73 x 35 x 110 mm
  • Weight Approx. 130 g
  • Number of modules that can be connected in series 64
  • Voltage supply 24 V DC, 18...28 V DC

EtherCAT interface

  • Number 2
  • Protocol EtherCAT according to IEC standard 61158
  • Physical layer Ethernet
  • Transmission rate 100 Mbps, full duplex
  • I/O image size 1024 bytes respectively
  • Connection RJ-45
  • Features
    • Automatic process data configuration,
    • Support of 'CANopen over EtherCAT' (CoE),
    • Object directory according to 'Modular Device Profile' (MDP),
    • Support of 'SDO Info' and 'Complete Access'
  • Diagnostic functions
    • cycle-current module diagnosis on the basis of module and channel status, subsequent module diagnosis on the basis of the diagnosis status in the object directory

USB interface

  • Number 1
  • Protocol Full-speed USB 1.1 device
  • Connection Mini-USB
  • Isolation voltage 1.5 kV
  • Electrical isolation Yes

Ambient conditions

  • Ambient temperature 0 °C … +60 °C
  • Transport and storage temperature -20 °C … +80 °C
  • Relative air humidity 95 % r H without condensation
  • Pollution degree 2
  • Protection rating IP 20
  • Certifications CE, UL pending

CE

  • Noise immunity DIN EN 61000-6-2 “EMC Immunity”
  • Interference emission DIN EN 61000-6-4 “EMC Emission”
  • Vibration and shock resistance DIN EN 60068-2-6:2008 „Vibration“, DIN EN 60068-2-27:2010 „Shock"
  • RoHS Yes
  • REACH Yes

 

SKU: HELMZ-600-185-1AA11

MPN: 600-185-1AA11

We strive to provide you with the best information we can, considering the images are not to scale and do not represent detailed perspectives of the respected products. If you notice any errors or omissions in this information, please let us know using the contact us tab on this page.
*
*
*

TB20 bus coupler EtherCAT

 

The EtherCAT bus coupler makes it possible to access data from peripheral modules using the EtherCAT protocol.
It can accommodate up to 64 modules of any kind connected in series with the bus coupler.
It detects peripheral modules that are plugged in and can assign the corresponding I/O data to an EtherCAT mapping automatically.
The EtherCAT bus coupler supports the Modular Device Profile.
A large I/O image table size of 1,024 bytes makes it possible toimplement comprehensive and complex systems.
TB20 ToolBox can be used to easily configure the system and the various module parameters and transfer the corresponding settings to the coupler.
Alternatively, the configuration can also be edited using the CoE object dictionary.
Finally, running TB20 systems can be diagnosed in real-time and set up for testing purposes if an EtherCAT master is not yet connected (simulation / I/O check).
A functioning TB20 configuration will always require a bus coupler and at least one peripheral module.

Note: Individual modules cannot be combined with the IO systems of other manufacturers.

General information

  • Dimensions (DxWxH) 73 x 35 x 110 mm
  • Weight Approx. 130 g
  • Number of modules that can be connected in series 64
  • Voltage supply 24 V DC, 18...28 V DC

EtherCAT interface

  • Number 2
  • Protocol EtherCAT according to IEC standard 61158
  • Physical layer Ethernet
  • Transmission rate 100 Mbps, full duplex
  • I/O image size 1024 bytes respectively
  • Connection RJ-45
  • Features
    • Automatic process data configuration,
    • Support of 'CANopen over EtherCAT' (CoE),
    • Object directory according to 'Modular Device Profile' (MDP),
    • Support of 'SDO Info' and 'Complete Access'
  • Diagnostic functions
    • cycle-current module diagnosis on the basis of module and channel status, subsequent module diagnosis on the basis of the diagnosis status in the object directory

USB interface

  • Number 1
  • Protocol Full-speed USB 1.1 device
  • Connection Mini-USB
  • Isolation voltage 1.5 kV
  • Electrical isolation Yes

Ambient conditions

  • Ambient temperature 0 °C … +60 °C
  • Transport and storage temperature -20 °C … +80 °C
  • Relative air humidity 95 % r H without condensation
  • Pollution degree 2
  • Protection rating IP 20
  • Certifications CE, UL pending

CE

  • Noise immunity DIN EN 61000-6-2 “EMC Immunity”
  • Interference emission DIN EN 61000-6-4 “EMC Emission”
  • Vibration and shock resistance DIN EN 60068-2-6:2008 „Vibration“, DIN EN 60068-2-27:2010 „Shock"
  • RoHS Yes
  • REACH Yes

 

SKU: HELMZ-600-185-1AA11

MPN: 600-185-1AA11